AJSM Click here for details!
HOME HELP CONTACT US SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Adam, F.
Right arrow Articles by Rupp, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Adam, F.
Right arrow Articles by Rupp, S.
Related Collections
Right arrow Imaging Studies
Right arrow Reconstruction
Right arrow Biomechanics
Right arrow Graft fixation
The American Journal of Sports Medicine 32:71-78 (2004)
© 2004 American Orthopaedic Society for Sports Medicine

Biomechanical Properties of Patellar and Hamstring Graft Tibial Fixation Techniques in Anterior Cruciate Ligament Reconstruction

Experimental Study With Roentgen Stereometric Analysis

Frank Adam, MD*, Dietrich Pape, MD, Karin Schiel, cand med, Oliver Steimer, MD, Dieter Kohn, MD, PhD and Stefan Rupp, MD, PhD

From the Department of Orthopaedic Surgery, Laboratory for Radiostereometric Analysis (RSA), Saarland University Medical Center, Homburg/Saar, Germany

* Address correspondence and reprint requests to Dr. Frank Adam, Universitätskliniken des Saarlandes, Orthopädische Klinik und Poliklinik, D-66421 Homburg/Saar, Germany.

Background: Reliable fixation of the soft hamstring grafts in ACL reconstruction has been reported as problematic.

Hypothesis: The biomechanical properties of patellar tendon (PT) grafts fixed with biodegradable screws (PTBS) are superior compared to quadrupled hamstring grafts fixed with BioScrew (HBS) or Suture-Disc fixation (HSD).

Study Design: Controlled laboratory study with roentgen stereometric analysis (RSA).

Methods: Ten porcine specimens were prepared for each group. In the PT group, the bone plugs were fixed with a 7 x 25 mm BioScrew. In the hamstring group, four-stranded tendon grafts were anchored within a tibial tunnel of 8 mm diameter either with a 7 x 25 mm BioScrew or eight polyester sutures knotted over a Suture-Disc. The grafts were loaded stepwise, and micromotion of the graft inside the tibial tunnel was measured with RSA.

Results: Hamstring grafts failed at lower loads (HBS: 536 N, HSD 445 N) than the PTBS grafts (658 N). Stiffness in the PTBS group was much greater compared to the hamstring groups (3500 N/mm versus HBS = 517 N/mm and HSD = 111 N/mm). Irreversible graft motion after graft loading with 200 N was measured at 0.03 mm (PTBS), 0.38mm (HBS), and 1.85mm (HSD). Elasticity for the HSD fixation was measured at 0.67 mm at 100 N and 1.32 mm at 200 N load.

Conclusion: Hamstring graft fixation with BioScrew and Suture-Disc displayed less stiffness and early graft motion compared to PTBS fixation. Screw fixation of tendon grafts is superior to Suture-Disc fixation with linkage material since it offers greater stiffness and less graft motion inside the tibial tunnel.

Clinical Relevance: Our results revealed graft motion for hamstring fixation with screw or linkage material at loads that occur during rehabilitation. This, in turn, may lead to graft laxity.

Key Words: anterior cruciate ligament • ACL • reconstruction • hamstrings • BPTB-graft • biomechanics • roentgen stereometric analysis • RSA




This article has been cited by other articles:


Home page
Am J Sports MedHome page
B. S. Dunkin, J. Nyland, A. R. Duffee, J. A. Brunelli, R. Burden, and D. Caborn
Soft Tissue Tendon Graft Fixation in Serially Dilated or Extraction-Drilled Tibial Tunnels: A Porcine Model Study Using High-Resolution Quantitative Computerized Tomography
Am. J. Sports Med., March 1, 2007; 35(3): 448 - 457.
[Abstract] [Full Text] [PDF]




HOME HELP CONTACT US SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Orthopaedic Society for Sports Medicine.