From the Orthopaedic Biomechanics Research Center, Childrens Hospital, San Diego, California
* Presented at the interim meeting of the AOSSM, Dallas, Texas, February 2002.
Address correspondence and reprint requests to Robert A. Pedowitz, MD, University of California, San Diego, Department of Orthopaedics 8894, 350 Dickinson Street, San Diego, CA 92103-8894
Background: In recent studies, investigators have used a cyclic loading model to investigate the efficacy of rotator cuff fixation modalities.
Hypothesis: A bioabsorbable poly-D-lactic acid screw and toothed washer implant will provide more stable fixation of rotator cuff repairs than standard suture anchor techniques.
Study Design: Controlled laboratory study.
Methods: Forty bovine shoulders (ages 3 to 6 months) had 1 x 2 cm defects created in the infraspinatus tendon. There were five repair groups (eight specimens per group) consisting of either two screw and washer implants or two suture anchors. Four suture techniques were tested: single-loaded anchors with simple sutures, double-loaded anchors with simple sutures, single-loaded anchors with horizontal mattress sutures, or single-loaded anchors with modified Mason-Allen sutures. Repairs were loaded at 5-second cycles from 10 to 180 N with use of a hydraulic testing machine. The number of cycles to gap formation of 5 and 10 mm was recorded.
Results: Gap formation of 5 and 10 mm occurred significantly later for the screw repair group than for any of the suture anchor groups. There was no significant difference between suture groups.
Conclusions: The bioabsorbable screw and washer provided more stable fixation than suture anchor techniques under isometric cyclic loading conditions.
Clinical Relevance: This is a time-zero study of implant performance. The results indicate that the implant may decrease clinical failures in the early postoperative period under standard rehabilitation protocols.
This article has been cited by other articles:
![]() |
O. Lorbach, F. Bachelier, J. Vees, D. Kohn, and D. Pape Cyclic Loading of Rotator Cuff Reconstructions: Single-Row Repair With Modified Suture Configurations Versus Double-Row Repair Am. J. Sports Med., August 1, 2008; 36(8): 1504 - 1510. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. S. Ahmad, C. Kleweno, A. M. Jacir, J. E. Bell, T. R. Gardner, W. N. Levine, and L. U. Bigliani Biomechanical Performance of Rotator Cuff Repairs With Humeral Rotation: A New Rotator Cuff Repair Failure Model Am. J. Sports Med., May 1, 2008; 36(5): 888 - 892. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Schimizzi, M. Wedemeyer, T. Odell, W. Thomas, A. T. Mahar, and R. Pedowitz Effects of a Novel Sterilization Process on Soft Tissue Mechanical Properties for Anterior Cruciate Ligament Allografts Am. J. Sports Med., April 1, 2007; 35(4): 612 - 616. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Koganti, G. J. Adamson, C. S. Gregersen, M. M. Pink, and J. A. Shankwiler Biomechanical Comparison of Traditional and Locked Suture Configurations for Arthroscopic Repairs of the Rotator Cuff Am. J. Sports Med., November 1, 2006; 34(11): 1832 - 1838. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. B. Park, E. Keyurapan, H. S. Gill, H. S. Selhi, and E. G. McFarland Suture Anchors and Tacks for Shoulder Surgery, Part II: The Prevention and Treatment of Complications Am. J. Sports Med., January 1, 2006; 34(1): 136 - 144. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. G. McFarland, H. B. Park, E. Keyurapan, H. S. Gill, and H. S. Selhi Suture Anchors and Tacks for Shoulder Surgery, Part 1: Biology and Biomechanics Am. J. Sports Med., December 1, 2005; 33(12): 1918 - 1923. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. C. Park, E. R. Cadet, W. N. Levine, L. U. Bigliani, and C. S. Ahmad Tendon-to-Bone Pressure Distributions at a Repaired Rotator Cuff Footprint Using Transosseous Suture and Suture Anchor Fixation Techniques Am. J. Sports Med., August 1, 2005; 33(8): 1154 - 1159. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | CONTACT US | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |