|
|
||||||||
Sign In to gain access to subscriptions and/or personal tools. |
|||||||||



,
* Medical School and Institute of Medical Technology, University of Tampere, Tampere, Finland
Department of Surgery, Tampere University Hospital, Tampere, Finland
Accident and Trauma Research Center and Tampere Research Center of Sports Medicine, Urho Kaleva Kekkonen Institute for Health Promotion Research, Tampere, Finland
Address correspondence and reprint requests to Markku Järvinen, MD, PhD, Department of Surgery, Medical School, University of Tampere, POB 607, 33101 Tampere, Finland
We evaluated the initial bone-patellar tendon-bone graft fixation strength of bioabsorbable as compared with titanium interference screws in anterior cruciate ligament reconstruction using matched pairs of porcine knees. Ten pairs underwent single-cycle failure loading at a rate of 50 mm/min, and 10 pairs underwent cyclic loading at half-hertz frequency. The cyclic loading started with 100 load cycles between 50 and 150 N. We then progressively increased loads in 50-N increments after each set of 100 cycles. After 100 cycles at 850 N, the specimens were loaded to failure at a rate of 50 mm/min. In the single-cycle failure loading test, the mean ultimate failure loads (±SD) for the bioabsorbable (837 ± 260 N) and titanium interference screws (863 ± 192 N) were not significantly different, nor were the mean yield loads or the stiffness of the fixation. In the cyclic loading test, the yield loads were 605 ± 142 N and 585 ± 103 N for the bioabsorbable and titanium interference screws, respectively (no significant difference). Although there was no significant difference in the ultimate failure load, more bone block fractures were found in the grafts fixed with a titanium interference screw. Bioabsorbable interference screw fixation thus seems to provide a reasonable alternative to titanium screws.
This article has been cited by other articles:
![]() |
G. B. Maletis, S. L. Cameron, J. J. Tengan, and R. J. Burchette A Prospective Randomized Study of Anterior Cruciate Ligament Reconstruction: A Comparison of Patellar Tendon and Quadruple-Strand Semitendinosus/Gracilis Tendons Fixed With Bioabsorbable Interference Screws Am. J. Sports Med., March 1, 2007; 35(3): 384 - 394. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Berkson, G. H. Lee, A. Kumar, N. Verma, B. R. Bach Jr, and N. Hallab The Effect of Cyclic Loading on Rotated Bone-Tendon-Bone Anterior Cruciate Ligament Graft Constructs Am. J. Sports Med., September 1, 2006; 34(9): 1442 - 1449. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. O. Drogset, T. Grontvedt, and A. Tegnander Endoscopic Reconstruction of the Anterior Cruciate Ligament Using Bone-Patellar Tendon-Bone Grafts Fixed With Bioabsorbable or Metal Interference Screws: A Prospective Randomized Study of the Clinical Outcome Am. J. Sports Med., August 1, 2005; 33(8): 1160 - 1165. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. S. B. Saweeres, J. H. Kuiper, R. O. Evans, J. B. Richardson, and S. H. White Predicting In Vivo Clinical Performance of Anterior Cruciate Ligament Fixation Methods From In Vitro Analysis: Industrial Tests of Fatigue Life and Tolerance Limits Are More Useful Than Other Cyclic Loading Parameters Am. J. Sports Med., May 1, 2005; 33(5): 666 - 673. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Zantop, A. K. Eggers, V. Musahl, A. Weimann, and W. Petersen Cyclic Testing of Flexible All-Inside Meniscus Suture Anchors: Biomechanical Analysis Am. J. Sports Med., March 1, 2005; 33(3): 388 - 394. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Camillieri, E. G. McFarland, L. E. Jasper, S. M. Belkoff, T. K. Kim, P. B. Rauh, and P. P. Mariani A Biomechanical Evaluation of Transcondylar Femoral Fixation of Anterior Cruciate Ligament Grafts Am. J. Sports Med., June 1, 2004; 32(4): 950 - 955. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Zantop, A. Weimann, M. Rummler, J. Hassenpflug, and W. Petersen Initial Fixation Strength of Two Bioabsorbable Pins for the Fixation of Hamstring Grafts Compared to Interference Screw Fixation: Single Cycle and Cyclic Loading Am. J. Sports Med., April 1, 2004; 32(3): 641 - 649. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T. Nurmi, H. Sievanen, P. Kannus, M. Jarvinen, and T. L. N. Jarvinen Porcine Tibia Is a Poor Substitute for Human Cadaver Tibia for Evaluating Interference Screw Fixation Am. J. Sports Med., April 1, 2004; 32(3): 765 - 771. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Verma, M. A. Noerdlinger, N. Hallab, C. A. Bush-Joseph, and B. R. Bach Jr. Effects of Graft Rotation on Initial Biomechanical Failure Characteristics of Bone-Patellar Tendon-Bone Constructs Am. J. Sports Med., September 1, 2003; 31(5): 708 - 713. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | CONTACT US | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |