|
|
||||||||
Sign In to gain access to subscriptions and/or personal tools. |
|||||||||
a Department of Orthopaedics and Rehabilitation, The Pennsylvania State University, Milton S. Hershey Medical Center, Hershey, Pennsylvania
* Address correspondence and reprint requests to Kevin P. Black, MD, Department of Orthopaedics and Rehabilitation, The Pennsylvania State University College of Medicine, Milton S. Hershey Medical Center, 500 University Drive, POB 850, MC H089, Hershey, PA 17033
Graft-tunnel mismatch during arthroscopically assisted anterior cruciate ligament reconstruction using the central-third patellar tendon results in less than 20 mm of bone plug remaining in the tibial tunnel. We decided to evaluate the strength of bone plug fixation using interference fit screws that were less than 20 mm in length. Biomechanical testing was performed on 48 porcine hindquarters using 9-mm diameter interference fit screws that measured 12.5, 15, and 20 mm in length. No significant difference was noted between the different-length screws for insertion torque, divergence, stiffness, displacement, or load to failure. We believe, therefore, that comparable graft fixation can be achieved in the tibial tunnel using 9-mm diameter interference fit screws that are less than 20 mm long, and that these shorter screws may be useful in cases of graft-tunnel mismatch.
This article has been cited by other articles:
![]() |
A. Harvey, N. P. Thomas, and A. A. Amis Fixation of the graft in reconstruction of the anterior cruciate ligament J Bone Joint Surg Br, May 1, 2005; 87-B(5): 593 - 603. [Full Text] [PDF] |
||||
![]() |
S. B. Bailey, D. M. Grover, S. M. Howell, and M. L. Hull Foam-Reinforced Elderly Human Tibia Approximates Young Human Tibia Better Than Porcine Tibia: A Study of the Structural Properties of Three Soft Tissue Fixation Devices Am. J. Sports Med., April 1, 2004; 32(3): 755 - 764. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T. Nurmi, H. Sievanen, P. Kannus, M. Jarvinen, and T. L. N. Jarvinen Porcine Tibia Is a Poor Substitute for Human Cadaver Tibia for Evaluating Interference Screw Fixation Am. J. Sports Med., April 1, 2004; 32(3): 765 - 771. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Verma, M. A. Noerdlinger, N. Hallab, C. A. Bush-Joseph, and B. R. Bach Jr. Effects of Graft Rotation on Initial Biomechanical Failure Characteristics of Bone-Patellar Tendon-Bone Constructs Am. J. Sports Med., September 1, 2003; 31(5): 708 - 713. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Honl, V. Carrero, E. Hille, E. Schneider, and M. M. Morlock Bone-Patellar Tendon-Bone Grafts for Anterior Cruciate Ligament Reconstruction: An in Vitro Comparison of Mechanical Behavior under Failure Tensile Loading and Cyclic Submaximal Tensile Loading Am. J. Sports Med., July 1, 2002; 30(4): 549 - 557. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | CONTACT US | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |