AJSM
HOME HELP CONTACT US SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Black, K. P.
Right arrow Articles by Jacobs, C. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Black, K. P.
Right arrow Articles by Jacobs, C. R.
Related Collections
Right arrow Reconstruction
Right arrow Graft fixation
The American Journal of Sports Medicine 28:846-849 (2000)
© 2000 American Orthopaedic Society for Sports Medicine

Effects of Interference Fit Screw Length on Tibial Tunnel Fixation for Anterior Cruciate Ligament Reconstruction

Kevin P. Black, MD*, Marnie M. Saunders, PhD, Keith C. Stube, MD, Mark J.R. Moulton, MD and Christopher R. Jacobs, PhD

a Department of Orthopaedics and Rehabilitation, The Pennsylvania State University, Milton S. Hershey Medical Center, Hershey, Pennsylvania

* Address correspondence and reprint requests to Kevin P. Black, MD, Department of Orthopaedics and Rehabilitation, The Pennsylvania State University College of Medicine, Milton S. Hershey Medical Center, 500 University Drive, POB 850, MC H089, Hershey, PA 17033

Graft-tunnel mismatch during arthroscopically assisted anterior cruciate ligament reconstruction using the central-third patellar tendon results in less than 20 mm of bone plug remaining in the tibial tunnel. We decided to evaluate the strength of bone plug fixation using interference fit screws that were less than 20 mm in length. Biomechanical testing was performed on 48 porcine hindquarters using 9-mm diameter interference fit screws that measured 12.5, 15, and 20 mm in length. No significant difference was noted between the different-length screws for insertion torque, divergence, stiffness, displacement, or load to failure. We believe, therefore, that comparable graft fixation can be achieved in the tibial tunnel using 9-mm diameter interference fit screws that are less than 20 mm long, and that these shorter screws may be useful in cases of graft-tunnel mismatch.




This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
A. Harvey, N. P. Thomas, and A. A. Amis
Fixation of the graft in reconstruction of the anterior cruciate ligament
J Bone Joint Surg Br, May 1, 2005; 87-B(5): 593 - 603.
[Full Text] [PDF]


Home page
Am J Sports MedHome page
S. B. Bailey, D. M. Grover, S. M. Howell, and M. L. Hull
Foam-Reinforced Elderly Human Tibia Approximates Young Human Tibia Better Than Porcine Tibia: A Study of the Structural Properties of Three Soft Tissue Fixation Devices
Am. J. Sports Med., April 1, 2004; 32(3): 755 - 764.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
J. T. Nurmi, H. Sievanen, P. Kannus, M. Jarvinen, and T. L. N. Jarvinen
Porcine Tibia Is a Poor Substitute for Human Cadaver Tibia for Evaluating Interference Screw Fixation
Am. J. Sports Med., April 1, 2004; 32(3): 765 - 771.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
N. Verma, M. A. Noerdlinger, N. Hallab, C. A. Bush-Joseph, and B. R. Bach Jr.
Effects of Graft Rotation on Initial Biomechanical Failure Characteristics of Bone-Patellar Tendon-Bone Constructs
Am. J. Sports Med., September 1, 2003; 31(5): 708 - 713.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
M. Honl, V. Carrero, E. Hille, E. Schneider, and M. M. Morlock
Bone-Patellar Tendon-Bone Grafts for Anterior Cruciate Ligament Reconstruction: An in Vitro Comparison of Mechanical Behavior under Failure Tensile Loading and Cyclic Submaximal Tensile Loading
Am. J. Sports Med., July 1, 2002; 30(4): 549 - 557.
[Abstract] [Full Text] [PDF]




HOME HELP CONTACT US SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Orthopaedic Society for Sports Medicine.