|
|
||||||||
Sign In to gain access to subscriptions and/or personal tools. |
|||||||||

Musculoskeletal Research Laboratory, Hand and Upper Limb Centre, St. Josephs Health Centre, London, Ontario, Canada
Presented at the annual meeting of The Canadian Orthopaedic Association, Quebec City, Quebec, Canada, May 1996.
Address correspondence and reprint requests to Graham J. W. King, MD, FRCSC, Hand and Upper Limb Centre, St. Josephs Health Centre, 268 Grosvenor Street, London, Ontario N6A 4L6, Canada
Clinical reports suggest that suture anchors can simplify repair of distal biceps tendon avulsions. In this study, fixation strengths of Mitek and Statak suture anchors were compared with strength of reattachment using transosseous suture tunnels in eight cadaveric radii. Cyclic loading and load-to-failure testing were performed: No specimen failed during testing to 50 N for 3600 cycles; however, four of the Mitek anchors and one of the Statak anchors protruded out of the medullary canal. The mean load to failure of the Mitek suture anchor complexes was 220 ± 54 N, that of the Statak suture anchor complexes was 187 ± 64 N, and that of the transosseous sutures was 307 ± 142 N. There was no significant difference in the failure load or mechanism of failure between the Statak and Mitek anchors. Transosseous sutures failed at significantly greater loads on static testing than the suture anchors. Cyclic loading results suggest that the bony fixation achieved using these three techniques should be sufficient to allow immediate passive mobilization of the elbow after surgery. Protrusion of the suture anchors out of the tuberosity during cyclic loading is a concern because of potential development of a gap at the repair site and interference with forearm rotation.
This article has been cited by other articles:
![]() |
P. R. Chavan, T. R. Duquin, and L. J. Bisson Repair of the Ruptured Distal Biceps Tendon: A Systematic Review Am. J. Sports Med., August 1, 2008; 36(8): 1618 - 1624. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kettler, M. J. Tingart, J. Lunger, and V. Kuhn Reattachment of the distal tendon of biceps: FACTORS AFFECTING THE FAILURE STRENGTH OF THE REPAIR J Bone Joint Surg Br, January 1, 2008; 90-B(1): 103 - 106. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J. Bisson, J. G. de Perio, A. E. Weber, M. T. Ehrensberger, and C. Buyea Is It Safe to Perform Aggressive Rehabilitation After Distal Biceps Tendon Repair Using the Modified 2-Incision Approach?: A Biomechanical Study Am. J. Sports Med., December 1, 2007; 35(12): 2045 - 2050. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kettler, J. Lunger, V. Kuhn, W. Mutschler, and M. J. Tingart Failure Strengths in Distal Biceps Tendon Repair Am. J. Sports Med., September 1, 2007; 35(9): 1544 - 1548. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. D. Mazzocca, K. J. Burton, A. A. Romeo, S. Santangelo, D. A. Adams, and R. A. Arciero Biomechanical Evaluation of 4 Techniques of Distal Biceps Brachii Tendon Repair Am. J. Sports Med., February 1, 2007; 35(2): 252 - 258. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. S. Idler, W. H. Montgomery III, D. P. Lindsey, P. A. Badua, G. F. Wynne, and S. A. Yerby Distal Biceps Tendon Repair: A Biomechanical Comparison of Intact Tendon and 2 Repair Techniques Am. J. Sports Med., June 1, 2006; 34(6): 968 - 974. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Spranklin, S. Elder, C. Boyle, and R. McLaughlin Comparison of a Suture Anchor and a Toggle Rod for Use in Toggle Pin Fixation of Coxofemoral Luxations J. Am. Anim. Hosp. Assoc., March 1, 2006; 42(2): 121 - 126. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Jeys, S. Korrosis, T. Stewart, and N. J. Harris Bone Anchors or Interference Screws?: A Biomechanical Evaluation for Autograft Ankle Stabilization Am. J. Sports Med., October 1, 2004; 32(7): 1651 - 1659. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. BALABAUD, C. RUIZ, J. NONNENMACHER, P. SEYNAEVE, P. KEHR, and E. RAPP Repair of Distal Biceps Tendon Ruptures Using a Suture Anchor and an Anterior Approach J Hand Surg Eur Vol., April 1, 2004; 29(2): 178 - 182. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. E. Lemos, E. Ebramzedeh, and R. S. Kvitne A New Technique: In Vitro Suture Anchor Fixation Has Superior Yield Strength to Bone Tunnel Fixation for Distal Biceps Tendon Repair Am. J. Sports Med., March 1, 2004; 32(2): 406 - 410. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Pereira, R. S. Kvitne, M. Liang, F. B. Giacobetti, and E. Ebramzadeh Surgical Repair of Distal Biceps Tendon Ruptures: A Biomechanical Comparison of Two Techniques Am. J. Sports Med., May 1, 2002; 30(3): 432 - 436. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Rupp, T. Georg, C. Gauss, D. Kohn, and R. Seil Fatigue Testing of Suture Anchors Am. J. Sports Med., March 1, 2002; 30(2): 239 - 247. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | CONTACT US | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |